Concrete background texture

Loadspan tables

Our Hollowcore and Beam & Block Load Span tables provided below are to be used as a guide only. Contact us for specific information regarding your project.

Hollowcore load span table

The spans indicated below have not been limited to 50 x unit depth usually used to minimise the dynamic movement in the planks.

We therefore do not recommend spans greater than the following: 150mm planks: 7.50m, 200mm planks: 10.00m & 250mm planks: 12.50m.
Spans that exceed this are shown in orange.

Our Hollowcore and Beam & Block Load Span tables provided below are to be used as a guide only. Contact us for specific information regarding your project.

  • Overall Structural Depth(mm)Unit Depth (mm)Self WeightSelf Weight + 1.5nN/m2 for Architectural Finishes (or other Dead load) + Imposed (Live) Load shown below
    0.751.52.02.53.04.05.010.015.0
    1501502.489.058.408.057.707.456.956.555.254.50
    1501502.958.507.957.657.357.106.656.305.104.40
    2002002.9710.7010.059.559.308.958.407.956.455.55
    2502503.4612.0011.3010.8510.5010.159.609.107.403
  • Overall Structural Depth(mm)Unit Depth (mm)Self Weight inc. Topping (Kn/m2)Self Weight + 1.5nN/m2 for Architectural Finishes (or other Dead load) + Imposed (Live) Load shown below
    0.751.52.02.53.04.05.010.015.0
    2001503.688.358.057.807.657.457.106.855.755.10
    2502004.179.909.459.208.958.758.358.156.805.95
    3002504.6611.0010.6010.3510.059.959.409.057.656.75
  • Overall Structural Depth(mm)Unit Depth (mm)Self Weight inc. Topping (Kn/m2)Self Weight + 1.5nN/m2 for Architectural Finishes (or other Dead load) + Imposed (Live) Load shown below
    0.751.52.02.53.04.05.010.015.0
    2001503.688.858.458.208.007.807.407.105.905.20
    2502004.1710.209.759.509.209.008.608.206.906.05
    3002504.6611.3510.8510.5510.3010.059.609.207.756.85

Beam and block load span tables

The load/span tables show the maximum clear span for both domestic and other loading conditions, such as nursing homes, hotels, and commercial developments.

These tables are provided as a guide only. Please Contact Us for specific information.

  • 155mm deep T beam (1 hour fire resistance) Medium Density Infill blocks 1450kg/m3Maximum Clear Span* in metres below allows for the characteristics live loads as stated + Self weight + 1.8 kN/m2(75mm Screed) finishes + 1.00 kN/m2 partition allowance
    Beam centres(mm)Block Spacing’Self-Weight (kN/m2)Imposed Live Load kN/m2
    0.751.502.002.53.004.005.007.50
    beam1510W1.783.753.503.303.203.052.852.702.35
    beam2398A1.884.203.903.753.603.453.253.052.70
    beam3285N2.064.954.604.404.204.153.803.603.15
    beam4620DW2.114.704.404.204.053.903.653.453.05
    beam5508DA2.265.154.804.604.454.254.003.803.35
    beam6395DN2.505.705.355.154.954.804.504.253.75
    beam7505TN2.756.105705.505.305.104.804.754.05

    *Clear span between supporting walls / **W = wid (440mm) A = Alternate (440+215) N = Narrow (215mm) / DW = Double beams Wide / DA = Double beams Alternate / DN = Double beams Narrow / TN = Triple beams Narrow

    Download/Print
  • 225mm deep T beam (1 hour fire resistance) Medium Density Infill blocks 1450kg/m3Maximum Clear Span* in metres below allows for the characteristics live loads as stated + Self weight + 1.8 kN/m2(75mm Screed) finishes + 1.00 kN/m2 partition allowance
    Beam centres(mm)Block Spacing’Self-Weight (kN/m2)Imposed Live Load kN/m2
    0.751.502.002.53.004.005.007.50
    beam8510W2.075.154.804.654.454.354.053.853.45
    beam9398A2.265.755.405.205.004.854.554.353.85
    beam10285N2.596.606.256.005.805.655.355.054.55
    beam11620DW2.606.355.955.755.555.405.104.854.35
    beam12508DA2.866.856.506.256.055.905.555.304.75
    beam13395DN3.277.557.156.956.756.556.205.905.30
    beam14505TN3.657.957.607.357.156.956.606.305.70

    *Clear span between supporting walls / **W = wid (440mm) A = Alternate (440+215) N = Narrow (215mm) / DW = Double beams Wide / DA = Double beams Alternate / DN = Double beams Narrow / TN = Triple beams Narrow

    Download/Print

WarmFloor Pro insulated concrete flooring

 

Did you know, we are also able to provide an insulated concrete flooring alternative over our traditional Beam and Block flooring solution?

Milbank employee installing Warm Floor Pro alternative flooring

WarmFloor Pro by Milbank Concrete Products is a cost-effective alternative to quickly constructing a thermally insulated concrete ground floor over the industry leading competitor. Reduced initial construction costs and increased energy savings make WarmFloor Pro a compelling alternative to a standard beam and block floor.